ENGINE SCREEN
The Engine screen displays the oil pressure, coolant temperature and battery voltage on three main gauges. Below
the gauges is an hour gauge displaying the total run time on the engine. At the bottom of the screen, this screen
also displays maintenance alarm status with the time remaining (black text) or the time past (red text) a scheduled
maintenance tasks, along with the description of the maintenance procedure and the action that will take place when
the timer trips the alarm.
Note: If the measured value is outside the range of a gauge, the needle will not be displayed. The digital value below
the gauge will still show the measured value.
Oil Press: Displays engine oil pressure. Current coolant temperature is displayed directly below the gauge
at all times. The gauge registers oil pressure between 0-100 psi (0-689 kPa). Normal operating pressure is
between 35-80 psi (241-552 kPa).
Coolant Temp: Displays engine coolant temperature. Current coolant temperature is displayed directly
below the gauge at all times. The gauge displays coolant temperature between 150°-250°F (66°-121°C).
Normal operating temperature of the unit is between 180°-200°F (82°-93°C) with an average ambient air
temperature of 70°F (21°C).
Battery: Displays the engine battery voltage. Current battery voltage is displayed directly below the gauge
at all times. The gauge displays battery voltage between 0-50V. A normal reading is 12-14V on 12 volt
systems and 24-26V on 24 volt systems (with the engine running).
GENERATOR SCREEN
The Generator screen displays the average voltage frequency, volts and amps from the generator, as well as line-
to-line voltage, and individual line-to-neutral voltage, amperage and power (kW). This screen also displays the
generator winding configuration set by the voltage selector switch in the lower right corner.
Note: When loading the generator, it is important to observe the amperage to determine the load balance on each
line of the generator. Minor load unbalances, usually ten percent or less, will not cause any particular problems.
Every effort should be made to distribute the load equally between all lines.
00394
GEN
V
+
-
Maintenance
Alarm Hours Description Action
1 174 To Service Oil Maintenance
2 174 To Service Fuel Maintenance
3 174 To Service Air Maintenance
Oil press. Coolant Temp. Battery
Manual Mode
Hrs
13.8
V
0
10
20 30
40
50150
170
190 210
230
250
°F
214
PSI
50.9
100
0
20
40 60
80
0 0 3 2 5 1 5
Warning
Shutdown
Electrical Trip
00395
Manual Mode
GEN
V
+
-
Parallel Low Zig-Zag
L1 (U)
L2 (W)
N
Volt Volt Amp kW
L1-L2 L1
L2-L3 L2
L3-L1 L3
IE
0
0
0
0
0
0
0
0
50
25
0.0
0.0
0.0
AmpVolt
Freq
0
10
20
30 40
50
60
70 0
88
175
263
350 0
13
25
38
50
Vista de pagina 21
1 2 ... 17 18 19 20 21 22 23 24 25 26 27 ... 59 60

Comentarios a estos manuales

Sin comentarios