17
1. DOCUMENT HOLDER
2. POWER ZONE™ CONTROLLER: Refer to “Power Zone™ Controller” on page 20.
3. AUXILIARY LIGHT SWITCHES (2) (Optional): These switches operate the control panel and interior lights.
4. 50A CIRCUIT BREAKERS (3): Circuit breakers for the 120/240V twist-lock receptacles.
5. 120V GFCI RECEPTACLES (2): Receptacles for additional equipment that may require Ground Fault Circuit
Interrupt (GFCI) protection.
6. 20A CIRCUIT BREAKERS (2): Circuit breakers for the 120V GFCI receptacles.
7. REMOTE START TERMINAL BLOCK: Used to connect the generator to a dry-contact closure switch for remote
starting of the unit.
8. CONNECTION FOR BATTERY CHARGER (Optional): Allows for 120VAC input to power an onboard battery
charger.
9. 120/240V TWIST-LOCK RECEPTACLES (3): These receptacles are used for connecting additional loads or
equipment to the generator in 240 and 208 voltage selections only.
10. CONNECTION FOR ENGINE BLOCK HEATER (Optional): Allows for 120VAC input to power the engine block
heater.
11. DOOR SAFETY SWITCH: The connection lug door is equipped with a safety interlock switch that will trip the
main circuit breaker and disable the voltage regulator if the door is opened while the unit is operating.
12. OUTPUT GROUND CONNECTION: Ground lug for attaching the generator to a good earthen ground.
13. CONNECTION TERMINAL LUGS (4): External loads can be wired to these lugs.
14. DIESEL EXHAUST FILTER CLEANING SWITCH: This switch toggles between enabling or disabling the auto
exhaust cleaning feature and entering manual regeneration. For additional information, refer to “Exhaust Filter
Cleaning Operations” on page 38.
15. MAIN CIRCUIT BREAKER FOR CONNECTION LUGS: This breaker will disconnect power to the connection
lugs (items 12-13). It WILL NOT disconnect power to the receptacles when the engine is running. The main
circuit breaker will trip in order to protect the generator from damage if a load is too great.